What is the process for Class II medical device MDACS registration in Hong Kong? What are the steps?
Release time:2025-04-28 16:17:38 The author: source:
The process for Class II medical device MDACS registration in Hong Kong involves several key steps, from preparing the required documents to submitting the application and ensuring compliance with regulatory standards. Here’s a detailed breakdown of the steps involved in the MDACS registration process for Class II medical devices:

The process for Class II medical device MDACS registration in Hong Kong involves several key steps, from preparing the required documents to submitting the application and ensuring compliance with regulatory standards. Here’s a detailed breakdown of the steps involved in the MDACS registration process for Class II medical devices:

1. Pre-Application Preparation

  • Determine Class II Classification: Ensure that your device is classified as Class II under Hong Kong’s medical device regulations. Class II devices are those that have a moderate risk to the user, such as thermometers, blood pressure monitors, and certain diagnostic tests.

  • Establish a Local Authorized Representative: If your company is located outside Hong Kong, you need to appoint a local authorized representative in Hong Kong who will submit the registration on your behalf.

  • Prepare Technical Documentation: Gather all relevant technical documents to demonstrate that the device complies with the requirements. These may include:

    • Device description, including intended use and design

    • Risk management files (compliance with ISO 14971)

    • Evidence of compliance with applicable standards (e.g., ISO 13485 for quality management, ISO 10993 for biocompatibility)

    • Clinical data or performance data (if applicable)

    • Labeling information, including instructions for use, packaging, and any safety warnings

  • Compliance with Standards: Ensure the device complies with applicable international standards (ISO, IEC) and Hong Kong-specific regulations.

2. Submit Application to MDCO

  • Application Submission: The registration application must be submitted to the Medical Device Control Office (MDCO) under the Department of Health in Hong Kong. Applications can be submitted electronically through the MDACS system, or in paper form if applicable.

  • Documents to Submit:

    1. Application Form: Complete the official MDACS registration form.

    2. Technical File: Submit all the technical documentation mentioned above.

    3. Authorized Representative Declaration: If applicable, submit proof of appointment of a local authorized representative.

    4. Manufacturing Information: Include details of the manufacturer and the manufacturing facility, along with a valid Good Manufacturing Practices (GMP) certificate or ISO 13485 certification.

    5. Product Labeling: Provide product labeling details, including packaging, instructions for use, and any safety-related information.

    6. Declaration of Conformity: Provide a declaration of conformity to applicable regulatory standards (e.g., ISO 13485).

    7. Clinical/Performance Data: Submit any clinical studies or data that support the safety and efficacy of the device, especially if the device is involved in diagnostics or therapeutic uses.

3. Application Review

  • MDCO Evaluation: The MDCO will review the submitted application and documentation to ensure the device complies with Hong Kong’s regulatory requirements. They may request additional information or clarifications if needed.

  • Safety and Performance Assessment: The MDCO will assess the device’s safety, performance, risk management procedures, and compliance with relevant international standards (such as ISO 13485, ISO 14971, etc.).

  • Post-Market Surveillance Plan: The MDCO will evaluate the manufacturer’s plan for post-market surveillance to ensure that the device’s safety and performance will continue to be monitored after it is placed on the market.

4. Approval and Registration

  • Issuance of Certificate: If the MDCO determines that the application meets all requirements, they will issue the MDACS registration certificate for the Class II medical device. The registration certificate allows the device to be marketed and sold in Hong Kong.

  • Registration Number: A unique registration number will be assigned to the device, which must be included on all marketing materials and packaging.

5. Post-Registration Compliance

  • Ongoing Post-Market Surveillance: Once the device is on the market, the manufacturer must continuously monitor its safety and effectiveness through post-market surveillance, as required by Hong Kong regulations.

  • Reporting Adverse Events: If any adverse events or safety concerns arise related to the device, these must be reported to the MDCO immediately, along with any corrective actions taken.

  • Changes to Device: If any significant changes are made to the device (such as a change in design, intended use, or manufacturing), these must be reported to the MDCO, and a new application may be required.

  • Renewal of Registration: The registration is valid for 5 years, after which it must be renewed by submitting an updated application and supporting documents to the MDCO.

6. Regulatory Fees

  • Fees for Registration: A fee is required for the registration application. The exact fee may vary based on the type of device and the level of regulatory review required. The fee schedule can be found on the MDCO website.

  • Payment: Pay the required fees at the time of submission.

7. Timeline for MDACS Registration

  • Processing Time: The processing time for Class II device registration can take several weeks to months, depending on the complexity of the application and whether additional information is needed. Typically, the process may take 4 to 6 months from submission to approval.


Summary of the Steps for MDACS Registration of a Class II Medical Device:

  1. Pre-Application Preparation:

    • Ensure compliance with applicable standards (ISO, IEC).

    • Appoint a local authorized representative (if applicable).

    • Gather and prepare technical documentation, labeling, and clinical data.

  2. Submit the Application:

    • Submit the completed application form, technical file, manufacturing details, labeling, and declaration of conformity to MDCO.

  3. MDCO Evaluation:

    • MDCO reviews and assesses the application and documentation.

  4. Approval and Registration:

    • MDCO issues the registration certificate and assigns a unique registration number.

  5. Post-Registration Compliance:

    • Maintain ongoing post-market surveillance, report adverse events, and renew registration as needed.


By following these steps and ensuring all necessary documentation is in order, manufacturers can successfully apply for and maintain Class II MDACS registration in Hong Kong, allowing their medical devices to be marketed and sold in the region.