What conditions must be met to apply for EU CE certification of medical devices?
Release time:2024-08-08 14:32:19 The author: source:
Determine the correct classification of your medical device (Class I, IIa, IIb, III) based on its intended use and potential risks. Different classes require varying levels of conformity assessment and involvement of Notified Bodies.

To apply for EU CE certification of medical devices, several conditions must be met to ensure compliance with European regulations. These conditions vary depending on the device class and the applicable regulatory framework (Medical Devices Directive (MDD) or Medical Devices Regulation (MDR)). Here are the key conditions that generally apply:

General Conditions:

  1. Device Classification:

    • Determine the correct classification of your medical device (Class I, IIa, IIb, III) based on its intended use and potential risks. Different classes require varying levels of conformity assessment and involvement of Notified Bodies.
  2. Conformity Assessment Route:

    • Identify the appropriate conformity assessment procedure based on the device class:
      • Class I Devices: Self-certification based on the manufacturer's declaration of conformity (Annexes II and VII).
      • Class IIa, IIb, III Devices: Involvement of a Notified Body for conformity assessment (Annexes II, IV, V, VI, or VII under MDR).
  3. Technical Documentation:

    • Prepare comprehensive technical documentation demonstrating conformity with essential requirements:
      • Device description and specifications
      • Design and manufacturing information
      • Risk assessment and mitigation measures
      • Clinical evaluation (if required)
      • Labeling and instructions for use
      • Quality management system documentation (ISO 13485:2016 compliance)
  4. Quality Management System (QMS):

    • Implement and maintain a QMS that complies with ISO 13485:2016 (or EN ISO 13485:2016) standards to ensure consistent production and conformity assessment.
  5. Clinical Evaluation (if applicable):

    • Conduct a clinical evaluation to demonstrate the device’s safety and performance based on clinical data, particularly for higher-risk classes (IIa, IIb, III under MDR).
  6. Notified Body Involvement (if applicable):

    • Engage with a Notified Body accredited under MDR or MDD for devices requiring assessment. The Notified Body reviews technical documentation, conducts audits (if necessary), and issues a conformity assessment certificate.
  7. Declaration of Conformity (DoC):

    • Prepare and sign a Declaration of Conformity stating that your device complies with relevant EU directives or regulations.
  8. CE Marking:

    • Affix the CE mark to your device and packaging once all requirements are met. The CE mark signifies compliance with EU regulations and allows market access within the European Economic Area (EEA).
  9. Post-Market Obligations:

    • Establish systems for post-market surveillance, vigilance, and corrective actions to monitor device performance and report incidents as required by EU regulations.

Specific Conditions under MDR:

  • Unique Device Identification (UDI): Compliance with UDI requirements for certain device classes under MDR.
  • Summary of Safety and Clinical Performance (SSCP): Preparation and maintenance of an SSCP summarizing clinical data and post-market surveillance information.
  • EUDAMED Database Registration: Depending on device class, registration of device and economic operator information in the EUDAMED database or with national competent authorities.

Additional Considerations:

  • Regulatory Updates: Stay informed about changes in EU medical device regulations to ensure ongoing compliance.
  • Documentation: Maintain comprehensive records of design, production, and conformity assessment activities.
  • Notified Body Selection: Choose a Notified Body with relevant expertise and accreditation to ensure efficient conformity assessment.

cdc-IFpQtennlj8-unsplash.jpg

Contact Us:

Whatsapp or Wechat:+86 15816864648;email address:hito.lin@grzan.cn