The procedures and steps for EU CE certification of Class D medical devices involve a comprehensive process to ensure compliance with the EU Medical Device Regulation (MDR). Here’s a detailed overview:
Determine Device Classification:
- Confirm that your device is classified as Class D under MDR, based on its intended use and risk to patients.
Prepare Technical Documentation:
- Design Dossier: Create a comprehensive Design Dossier, including:
- Device description and specifications.
- Risk management and mitigation strategies.
- Clinical evaluation reports, including clinical trials if needed.
- Performance and safety data.
- Manufacturing processes and quality control measures.
- Instructions for use and labeling.
Implement Quality Management System (QMS):
- Establish and maintain a QMS compliant with ISO 13485 or equivalent, covering all aspects of device design, manufacturing, and post-market activities.
Select a Notified Body:
- Choose a Notified Body designated for Class D devices. Ensure they are accredited to evaluate devices of your type and complexity.
Submit Application to Notified Body:
- Prepare and submit your application along with the Design Dossier to the selected Notified Body. This includes providing all necessary documentation and supporting evidence.
Assessment by Notified Body:
- Review of Documentation: The Notified Body reviews the Design Dossier and other submitted documents.
- Audits: The Notified Body may conduct an on-site audit of your facilities, processes, and QMS.
- Evaluation: They assess the clinical data and overall compliance with MDR requirements.
Address Non-Conformities:
- If the Notified Body identifies any issues, you must address them and provide corrective actions or additional information as requested.
Certification:
- Upon successful assessment, the Notified Body issues a CE certificate, allowing you to affix the CE mark to your device. This signifies compliance with MDR and authorization for market access in the EU.
Post-Market Surveillance:
- Implement a post-market surveillance system to monitor the device’s performance in the market. Collect and analyze feedback, report adverse events, and ensure ongoing compliance with MDR requirements.
Periodic Review and Updates:
- Regularly review and update your Technical Documentation, QMS, and clinical evaluations to ensure continued compliance. Prepare for periodic audits by the Notified Body.

Contact Us:
Whatsapp or Wechat:+86 15816864648;email address:hito.lin@grzan.cn