For Class C medical device registration with the Central Drugs Standard Control Organization (CDSCO) in India, you need to prepare and submit a comprehensive set of documents. Here's a detailed list of required documents and guidance on how to prepare your application files:
Required Documents
Application Form
- Completed Form: Filled out online through the SUGAM portal.
Technical Documentation
- Device Description: Detailed description of the device including its intended use, design, and mode of action.
- Technical File: Includes design documentation, manufacturing processes, and materials used.
- Product Specifications: Detailed technical and performance specifications of the device.
Clinical Evaluation Report
- Clinical Data: Evidence from clinical trials or studies demonstrating the safety and efficacy of the device.
- Clinical Study Reports: Detailed reports of any clinical trials conducted, including methodology, results, and conclusions.
Risk Management File
- Risk Assessment: Documentation of risk analysis and management, including identified risks and mitigation strategies.
- Risk Management Plan: Detailed plan for managing risks throughout the device lifecycle.
Quality Management System Certifications
- ISO 13485: Certificate of compliance with ISO 13485, which covers quality management systems for medical devices.
- GMP Compliance: Evidence of compliance with Good Manufacturing Practices (GMP).
Labeling and Packaging Information
- Labels: Detailed labels including the device name, intended use, manufacturer information, warnings, and instructions for use.
- Packaging: Information on packaging materials and methods to ensure device safety and integrity.
Manufacturing License
- Copy of Manufacturing License: Issued by the regulatory authority in the country where the device is manufactured.
Import License (if applicable)
- Import License: For devices being imported into India, provide a copy of the import license issued by CDSCO.
Authorization Letter
- Letter of Authorization: If applicable, from the foreign manufacturer authorizing the Indian applicant to act on their behalf.
Product Literature
- Brochures and Technical Data Sheets: Detailed product literature that describes the device and its uses.
How to Prepare the Application Files
Document Compilation
- Organize Files: Compile all necessary documents in a structured format. Ensure each document is complete and accurate.
- File Naming: Name files clearly and consistently to reflect their content, e.g., "Clinical_Evaluation_Report.pdf".
Formatting
- Document Format: Prepare documents in PDF or other accepted formats. Ensure they are legible and properly formatted.
- Technical File: Organize the technical file into sections such as device description, specifications, and design information.
Electronic Submission
- SUGAM Portal: Upload all documents to the SUGAM portal in the specified format. Follow the portal’s guidelines for file size and type.
- Verify Uploads: Ensure that all files are correctly uploaded and accessible.
Compliance Check
- Regulatory Guidelines: Cross-check all documents against CDSCO’s regulatory guidelines to ensure compliance.
- Consultation: Consider consulting with a regulatory expert to review the application and ensure completeness.
Review and Finalize
- Internal Review: Conduct a thorough review of the application and all documents before submission.
- Final Checks: Verify that all required documents are included and properly filled out.
Submission and Tracking
- Submit Application: Once all documents are prepared and reviewed, submit the application through the SUGAM portal.
- Track Status: Use the SUGAM portal to track the status of your application and respond to any requests for additional information promptly.

Contact Us:
Whatsapp or Wechat:+86 15816864648;email address:hito.lin@grzan.cn