The process for MDACS (Medical Device Administrative Control System) registration of Class IV in vitro diagnostic (IVD) medical devices in Hong Kong involves several key steps to ensure that the device meets regulatory requirements and is safe for use. Here’s a detailed overview of the MDACS registration process, including the essential steps involved:
MDACS Registration Process
Determine Device Classification:
- Confirm that your device is classified as a Class IV IVD according to the Medical Device Ordinance (Cap. 663). Understanding the classification is crucial, as it determines the registration requirements.
Prepare Technical Documentation:
- Compile the necessary technical documents, which include:
- Device description and intended use.
- Manufacturing information and quality management system (QMS) details (ISO 13485).
- Clinical evaluation and performance data.
- Risk management documentation (ISO 14971).
- Labeling and instructions for use (IFU).
- Stability and shelf-life data.
- Manufacturer information, including regulatory status.
Establish a Quality Management System (QMS):
- Ensure that your organization complies with ISO 13485, implementing effective quality management practices to manage the design, manufacturing, and post-market activities of the device.
Conduct Pre-Submission Review:
- Review all prepared documents for completeness and compliance with MDCO guidelines.
- Consider conducting an internal audit to identify any gaps in documentation or processes.
Submit Application:
- Submit the MDACS registration application to the Medical Device Control Office (MDCO), including:
- Completed application form.
- Required technical documentation.
- Payment of the applicable application fees.
MDCO Review:
- Upon receiving your application, the MDCO will review the submitted documents to ensure they meet regulatory standards.
- Be prepared to respond to any inquiries or requests for additional information from the MDCO during this review phase.
Address Queries and Provide Additional Information:
- If the MDCO raises any concerns or questions about the application, provide the requested information promptly and thoroughly.
Approval Notification:
- If the application is approved, the MDCO will issue a registration certificate, allowing you to market and distribute the device in Hong Kong.
- You may receive specific conditions or requirements that must be adhered to after registration.
Implement Post-Market Surveillance:
- Once registered, implement a post-market surveillance plan to monitor the device's performance and safety.
- Collect data on adverse events and user feedback, and ensure a process for reporting any incidents to the MDCO.
Maintain Ongoing Compliance:
- Continuously monitor and maintain compliance with the regulatory requirements, including conducting periodic reviews, updates, and renewals as necessary.
- Stay informed about changes in regulations that may impact your device and be prepared to submit updates if there are modifications to the device or its intended use.
Summary
The MDACS registration process for Class IV IVD medical devices involves careful preparation, submission, and ongoing compliance efforts. By following these steps, manufacturers can navigate the regulatory landscape effectively and ensure their devices meet the necessary safety and effectiveness standards for the Hong Kong market.
.jpg)
Contact Us:
Whatsapp or Wechat:+86 15816864648;email address:hito.lin@grzan.cn